799223588@qq.com
18611648453    

JCB-2 of Transformer oil micro moisture on-line monitoring sensor

Product Center > Oil moisture sensor > JCB-2 of Transformer oil micro moisture on-line monitoring sensor

JCB-2 of Transformer oil micro moisture on-line monitoring sensor

Summarize

Power transformers and reactors are valuable assets in the power industry. Real-time monitoring of trace moisture in insulating oil plays a vital role in the safe operation of these valuable assets. Because the existence of moisture will reduce the breakdown voltage of insulating oil and increase dielectric loss, accelerate the degradation and aging of polymer insulation materials, thus reducing the various properties of the insulation system. In serious cases, it will cause insulation breakdown and partial discharge, affecting the safe operation of the power system. JCB-2 adopts the world's advanced moisture and temperature detection devices, which can continuously, accurately and rapidly measure the water activity, micro-water content and temperature in oil under harsh environment.

Advantage

Continuous rapid detection of water activity (aw) in oil Accurate measurement of micro-water content (ppm) in oil Long-term stable operation in harsh environment Convenient local calibration function High oil resistance and pressure resistance Compact structure and easy integration Multi-mode signal output

Application

Electric power industry monitoring transformer and reactor insulating oil Industrial machinery monitors lubricating oil and hydraulic oil of mechanical equipment The transportation industry monitors engine oil of ships and vehicles.Technical parameter

Water activity


Measuring range:0 ... 1aw Measurement accuracy:0 ... 0.6 aw   ±0.02 aw; 0.6 aw … 0.9 aw   ± 0.03 aw; 0.9 aw … 1 aw  ± 0.04 aw Response time (typical): < 1 minute

Moisture in oil


Measurement range: 0…500 ppm (for mineral transformer oil) Measurement accuracy:± 10%

Temperature


Measurement Range: ‐ 40 ~ 80 ℃
Accuracy (at+25 ) :0.2  ℃
Operating temperature: ‐ 40~+60  ℃
Storage temperature: ‐ 40 ~+80  ℃
Allowable oil temperature :‐ 40~+120  ℃

Output


Digital Signal:RS485 (Modbus-RTU
Analog signal:4mA~20 mA, 0~20mA ,resistor load < 500Ω

Other


Measuring interface:G1/2 "ISO or G1/2" NPT Pressure range: Up to 100bar Probe material:316 stainless steel Protection grade:IP66 Power supply: 9V‐36V DC
Power supply current: < 5mA+ load current Transmitter weight: < 200g Total package weight:  <270 g Cable specification: M12,5 core Cable length: 2 meters Follow standard: CE certification EN61326 ‐ 1、 EN61326 ‐ 2 ‐ 3、 ICES ‐ 003、 Class B