Product Name: Intelligent Terminal-Protocol Converter
Product model: JCS-1000
Description of functions:Industrial equipment networking, protocol conversion, data acquisition, etc.
Applicable occasions:Power distribution automation, factory automation, internet of things, smart home, photovoltaic power generation, smart security, energy management, etc.
Interface description:1x10M/100M port, 2*RS232/RS485 composite serial port, 9~36V DC power input, port serial port light transceiver
Hardware parameters:
CPU memory Flash
ARM926EJ, main frequency 240MHz, 32MByte high performance memory, 128mbyte slcfash
Net port
One 100M/10M Ethernet interface supports AUTO MDI/MDIX dual-level lightning protection:
supports level 3 2KV protection tested by 10/700uS in GB/T 17626.5-2008 standard
±15kV Human Body Model
±15kV IEC1000-4-2 Air Discharge
RS485 interface
Two fully isolated RS485 interfaces (supporting receiving and sending indicator lights) RS485 adopts three-level protection:
supports the highest level of 4KV protection tested by 10/700uS in GB/T 17626.5-2008 standard
±15kV Human Body Model
±15kV IEC1000-4-2 Air Discharge
RS232 interface
2 fully isolated RS232 interfaces (2 fully isolated RS232 interfaces and RS485 are multiplexed):
±15kV Human Body Model
±15kV IEC1000-4-2 Air Discharge
Power interface
Supports 2 kinds of power interfaces:
standard 5.08mm spacing 3PIN european terminal interface
DC base 5.5mm*2.1mm
Input voltage: DC 9~36V
Power protection:
GB/T 17626.5-2008 standard grade 4 (4KV)8/20uS lightning strike test
anti-reverse connection protection
overvoltage protection
anti-burst protection
antistatic:
Ø ±15kV Human Body Model
Ø ±15kV IEC1000-4-2 Air Discharge
Power consumption
Maximum power consumption ≤3W
size
109mm×87mm×27mm(L×W×H) without hanging ears
Working temperature:-40~85℃
Storage and transportation temperature:-40~85℃
Operating relative humidity:20% ~ 90% without condensation
Relative humidity of storage and transportation: 15% ~ 95% without condensation
Software parameters:
Operating system
Embedded Linux
Support agreement
Acquisition protocol
Forwarding protocol
ModbusRTU
ModbusTCP
Department v issued CDT/DISA3
IEC60870-5-101
IEC60870-5-102 (customized information required)
IEC60870-5-103 (customized information required)
IEC60870-5-104
DL/T 645
shenyang wayne wireless temperature measurement
Other private protocols
ModbusRTU
ModbusTCP
IEC60870-5-101
IEC60870-5-104
MQTT
Other private protocols
Default dot number
remote communication: 4096
telemetry: 2048
remote control: 512
remote adjustment: 512
Telemetry coefficient
Support
Remote communication point number combination
Support remote signaling point number combination into a new point number
PC Configuration Software
based on Windows operating system
network-based remote configuration
supports remote upgrade and parameter configuration.
supports remapping of sub-site number and main site number
supports real-time monitoring and recording of messages
Upper computer software
As shown in the following figure:
Typical applications:
Distribution automation
Application description of distribution network automation:
The V-protocol converter converts the protocol of the protection device in the on-column switch into IEC60870-5-101 (or 104) protocol
The IEC 60870-5-101 protocol supports South Network Balanced, National Network Unbalanced, DTU Access Verification
The iec 60870-5-104 protocol supports the main stations of manufacturers such as nanrui, Shandong jicheng and sifang.